Upon request each system can be supplied as manual configuration.
High pressure side prime and purge valves in eluent and reagent flow.
Based on chemical processregeneration of suppressors with acid.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
The IONUS can be equipped with an additional UV/VIS detector.
Programmable thermostat for column (and suppressors).
Technical Specifications | |
---|---|
method | ion exchange chromatography of anions and cations in subsequent mode |
manual injection | 20 µL, further injection loops upon request (50 µL, 100 µL, 200 µL) |
autosampler | 2 racks, each of them with space for 48 vials (1.5 mL) or 12 vials (6 mL), sample cooling, loop 100 µL, 3 injection modes (full-loop, partial loop, microliter-pickup) |
column | stainless steel / PEEK |
temperature stability / range | ~ 0.5 °C / ambient up to 50 °C |
detection | conductivity detector: noise: 0.02 µS, 1s | linearity: < 1 s | range: 0 - 10 mS/cm effective cell volume: 1 µL, conductivity block: 30 °C |
isocratic pump system | max. pressure: 400 bar | flow rate: 0.01 - 10.00 mL/min reproducibility of flow rate: 0.1 % RSD at 100 µL/min |
maximum operating pressure | 120 bar |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1000 x 350 x 375 mm*, 60 kg, 110 - 230 V, 50/60 Hz |
*800 mm with opened main unit |
Chromatographic separation of amino acids is performed by ion exchange chromatography, followed by detection of ions by conductivity or indirect UV measurement.
The samples for the IONUS are mainly water-based. Analyses according to EPA 300 Part A and Part B are standard.
The autsoampler includes 2x 48 sample vials, which have a capacity of 1.5 mL. For small sample volumes, inlets can be used for the sample vials to ensure proper sample collection.
The system has an alarm system with three different levels. At "yellow" the user is informed about a situation that is not critical, at "orange" a controlled shutdown of the system is performed and at "red" the system is secured against serious damage by emergency shutdown.
The system works with a pre-sequence, the analysis sequence and a post-sequence. When the measurement sequence is completed, the system goes into standby and runs a circulation to keep the system in an equilibrated state to be able to start a new measurement again as quickly as possible.
We would like to improve the contact to our customers & partners and send you information and updates about our company and our products
membraPure endeavours as far as reasonably possible to provide correct and complete information on this website. However, membraPure does not guarantee that the information provided is up-to-date, correct and complete. The same applies to the content of external websites that this site refers to directly or indirectly via hyperlinks, programmes, files, contents or hyperlinks to other websites are provided without any expressed or implied warranty.
Contact Us
membraPure reserves the right to alter the information provided on this site without prior notice.
membraPure GmbH, Wolfgang-Kuentscher Str. 14, 16761 Hennigsdorf